We perform a wide range of isocyanate analysis during thermal decomposition of materials, from mono- and diisocyanate monomers to higher molecular weight isocyanate oligomers and adducts. This analysis can be used to indicate whether there is a risk for exposure to isocyanates, when exposing the material in question to elevated temperatures. The analysis is especially useful when the possible contents of isocyanates are unknown.

The standard procedure is a qualitative determination of the emission of the below specified isocyanates, when heating the material in question. A quantitative determination may also be performed per request.

Routine analysis package Reporting limit
Isocyanic acid (ICA) 2.0 µg total amount in the sample
Methyl isocyanate (MIC) 0.4 µg total amount in the sample
Ethyl isocyanate (EIC) 0.4 µg total amount in the sample
Propyl isocyanate (PIC) 0.4 µg total amount in the sample
Phenyl isocyanate (PHI) 0.4 µg total amount in the sample
1.6-Hexamethylene diisocyanate (1.6-HDI) 0.2 µg total amount in the sample
2.4-Toluene diisocyanate (2.4-TDI) 0.2 µg total amount in the sample
2.6-Toluene diisocyanate (2.6-TDI) 0.2 µg total amount in the sample
Isophorone diisocyanate (IPDI) 0.2 µg total amount in the sample
4.4’-Methylenediphenyl diisocyanate (4.4’-MDI) 0.2 µg total amount in the sample
Extended analysis package No 1 Reporting limit
HDI-Biuret 0.2 µg total amount in the sample
HDI-Isocyanurate 0.2 µg total amount in the sample
HDI-Uretidione 0.2 µg total amount in the sample
IPDI-Isocyanurate (trimer) 0.2 µg total amount in the sample
Extended analysis package No 2 Reporting limit
2.4’-Methylenediphenyl diisocyanate (2.4’-MDI) 0.2 µg total amount in the sample
MDI-3-ring-oligomer 0.2 µg total amount in the sample
MDI-4-ring- oligomer 0.2 µg total amount in the sample
Extended analysis package No 3 Reporting limit
H12-MDI (HMDI) 0.2 µg total amount in the sample
Extended analysis package No 4 Reporting limit
m-TMXDI (1.3-Bis(2-isocyanato-2-propyl)benzene) 0.2 µg total amount in the sample
Extended analysis package No 5 Reporting limit
m-XDI (m-xylylene diisocyanate) 0.2 µg total amount in the sample
Extended analysis package No 6 Reporting limit
2.6-DIP (2.6-Diisopropylphenyl isocyanate) 0.2 µg total amount in the sample
Extended analysis package No 7 Reporting limit
1.5-Naphthalene diisocyanate 0.2 µg total amount in the sample
Extended analysis package No 8 Reporting limit
P-TSI (p-Toluenesulfonyl isocyanate) 0.2 µg total amount in the sample
Extended analysis package No 9 Reporting limit
TODI (4.4'-Diisocyanato-3.3'-dimethylbiphenyl) 0.2 µg total amount in the sample
Package information Details
Prices Please contact us for further details
Standard response time 10 working days
Fastest response time 3 working days
Sample type Material/Work environment
Analysis type Organic compounds
Sampler Not applicable
Express tariff 100%
ISO-Standard 17734-1
Analysis method LC-MSMS